ALARM CAUSE
SOLUTION
INTERVENTION
AL 8 - FAILURE
DEPRESS
Obstructed exhaust
The exhaust chimney is partially or totally obstructed.
Call en expert stove-repairer who executes a check
from the exhaust up to the chimney pot.
Fume fan out of order
The pellet can burn also thanks to the chimney flue
depression without the aid of the fan. Have the
fume fan immediately replaced. It can be noxious to
health to let the stove running without fan.
Obstructed connecting
nozzle
Clean the connecting nozzle.
Faulty pressostat
Replace the pressostat.
Faulty electronic board Replace the mother board.
Extreme chimney lenght
Contact an expert stove repairer and check that the
exhaust chimney is in compliance with regulations:
see
CHIMNEY FLUE a pag. 51
.
Advers whether
conditions
In case of strong wind there can be a negative
pressure to the chimney. Check and switch the stove
on again.
The fire door is not
correctly closed
Close the fire door correctly and check if the gaskets
are broken.
Fire door microswitch
faulty or out of order
Replace the fire door microswitch.